REFRIGERANT • PT DATA v1

R-426A

PT data, curve stats, and quick routes into the field calculators. Data shown here is derived from the versioned PT asset set under /assets/pt/v1.

At a glance

SAFETY •
CURVE • bubble
POINTS • 371
GWP
ODP
Curves available
Dew + Bubble
Pressure range (psig)
-14.64 to 567.13
Temperature range (°F)
-160 to 210
Note: PT points are stored in psig and °F. For blends, bubble and dew represent different saturation states. Always follow OEM charging procedures.

Quick actions

These routes are designed to be technician-friendly: minimal taps, prefilled context, and predictable URLs for bookmarks and sharing.

Open PT Chart
Fast lookup (pressure ↔ temp)
Open →
Browse Equipment
See equipment using this refrigerant
Open →
Superheat/Subcool
Preselect this refrigerant
Open →
Charge Calculator
Line set adjustments
Open →
Curve toggle
Tip: For blends, evaporator saturation is typically based on dew, and condenser saturation is typically based on bubble.

Pressure → Saturation temperature (quick)

Linear interpolation between nearest points. Out-of-range values show “—”.

Pressure (psig)Sat Temp (°F)Source
0-19.2linear
2524.7linear
5050.2linear
7568.9linear
10084linear
150108linear
200127linear
250142.9linear
300156.7linear
350168.9linear
400179.8linear
450189.8linear

Temperature → Saturation pressure (quick)

Useful for “I have a target saturation temp—what pressure should I see?” checks.

Temp (°F)Sat Pressure (psig)Source
-40-6.3exact
-20-0.3exact
08.6exact
2021.3exact
4038.9exact
6062.4exact
8092.9exact
100131.8exact
120180.4exact
140240.2exact

Data source & notes

PT asset ID
r426a
Original name
R-426A
CAS
Units
psig / F (atm: 14.6959 psi)
Default curve
dew
PT index version
v1(from /assets/pt/v1/index.json)
Safety note: PT lookups are a foundational building block for charging and diagnostics, but they do not replace OEM procedures or full system context.