REFRIGERANT • PT DATA v1

R-123

PT data, curve stats, and quick routes into the field calculators. Data shown here is derived from the versioned PT asset set under /assets/pt/v1.

At a glance

SAFETY • B1
CURVE • dew
POINTS • 521
GWP
77
ODP
0.02
Curves available
Dew + Bubble
Pressure range (psig)
-14.7 to 503.96
Temperature range (°F)
-160 to 360
Note: PT points are stored in psig and °F. For blends, bubble and dew represent different saturation states. Always follow OEM charging procedures.

Quick actions

These routes are designed to be technician-friendly: minimal taps, prefilled context, and predictable URLs for bookmarks and sharing.

Open PT Chart
Fast lookup (pressure ↔ temp)
Open →
Browse Equipment
See equipment using this refrigerant
Open →
Superheat/Subcool
Preselect this refrigerant
Open →
Charge Calculator
Line set adjustments
Open →
Curve toggle
Tip: For blends, evaporator saturation is typically based on dew, and condenser saturation is typically based on bubble.

Pressure → Saturation temperature (quick)

Linear interpolation between nearest points. Out-of-range values show “—”.

Pressure (psig)Sat Temp (°F)Source
082.1linear
25137.3linear
50169.5linear
75193.3linear
100212.5linear
150243.2linear
200267.4linear
250287.8linear
300305.5linear
350321linear
400335linear
450347.7linear

Temperature → Saturation pressure (quick)

Useful for “I have a target saturation temp—what pressure should I see?” checks.

Temp (°F)Sat Pressure (psig)Source
-40-14.2exact
-20-13.6exact
0-12.7exact
20-11.2exact
40-8.9exact
60-5.5exact
80-0.6exact
1006.1exact
12015.1exact
14026.8exact

Data source & notes

PT asset ID
r123
Original name
R-123
CAS
306-83-2
Units
psig / F (atm: 14.6959 psi)
Default curve
dew
PT index version
v1(from /assets/pt/v1/index.json)
Safety note: PT lookups are a foundational building block for charging and diagnostics, but they do not replace OEM procedures or full system context.