REFRIGERANT • PT DATA v1
R-1234YF
PT data, curve stats, and quick routes into the field calculators. Data shown here is derived from the versioned PT asset set under /assets/pt/v1.
At a glance
SAFETY • A2L
CURVE • dew
POINTS • 261
GWP
4
ODP
Curves available
Dew + Bubble
Pressure range (psig)
-9.58 to 462.63
Temperature range (°F)
-60 to 200
Note: PT points are stored in psig and °F. For blends, bubble and dew represent different saturation states. Always follow OEM charging procedures.
Quick actions
These routes are designed to be technician-friendly: minimal taps, prefilled context, and predictable URLs for bookmarks and sharing.
Pressure → Saturation temperature (quick)
Linear interpolation between nearest points. Out-of-range values show “—”.
| Pressure (psig) | Sat Temp (°F) | Source |
|---|---|---|
| 0 | -21.1 | linear |
| 25 | 24.5 | linear |
| 50 | 51.1 | linear |
| 75 | 70.7 | linear |
| 100 | 86.6 | linear |
| 150 | 111.8 | linear |
| 200 | 131.8 | linear |
| 250 | 148.6 | linear |
| 300 | 163 | linear |
| 350 | 175.8 | linear |
| 400 | 187.3 | linear |
| 450 | 197.6 | linear |
Temperature → Saturation pressure (quick)
Useful for “I have a target saturation temp—what pressure should I see?” checks.
| Temp (°F) | Sat Pressure (psig) | Source |
|---|---|---|
| -40 | -5.6 | exact |
| -20 | 0.4 | exact |
| 0 | 9.2 | exact |
| 20 | 21.6 | exact |
| 40 | 38.4 | exact |
| 60 | 60.6 | exact |
| 80 | 89 | exact |
| 100 | 124.9 | exact |
| 120 | 169.2 | exact |
| 140 | 223.4 | exact |
Data source & notes
PT asset ID
r1234yfOriginal name
R-1234YF
CAS
754-12-1
Units
psig / F (atm: 14.6959 psi)
Default curve
dew
PT index version
v1(from /assets/pt/v1/index.json)Safety note: PT lookups are a foundational building block for charging and diagnostics, but they do not replace OEM procedures or full system context.