REFRIGERANT • PT DATA v1

R-428A

PT data, curve stats, and quick routes into the field calculators. Data shown here is derived from the versioned PT asset set under /assets/pt/v1.

At a glance

SAFETY •
CURVE • dew
POINTS • 311
GWP
ODP
Curves available
Dew + Bubble
Pressure range (psig)
-14.46 to 485.84
Temperature range (°F)
-160 to 150
Note: PT points are stored in psig and °F. For blends, bubble and dew represent different saturation states. Always follow OEM charging procedures.

Quick actions

These routes are designed to be technician-friendly: minimal taps, prefilled context, and predictable URLs for bookmarks and sharing.

Open PT Chart
Fast lookup (pressure ↔ temp)
Open →
Browse Equipment
See equipment using this refrigerant
Open →
Superheat/Subcool
Preselect this refrigerant
Open →
Charge Calculator
Line set adjustments
Open →
Curve toggle
Tip: For blends, evaporator saturation is typically based on dew, and condenser saturation is typically based on bubble.

Pressure → Saturation temperature (quick)

Linear interpolation between nearest points. Out-of-range values show “—”.

Pressure (psig)Sat Temp (°F)Source
0-53.5linear
25-12.4linear
5011.6linear
7529.3linear
10043.7linear
15066.4linear
20084.4linear
25099.5linear
300112.6linear
350124.2linear
400134.5linear
450143.9linear

Temperature → Saturation pressure (quick)

Useful for “I have a target saturation temp—what pressure should I see?” checks.

Temp (°F)Sat Pressure (psig)Source
-406.2exact
-2018.9exact
036.7exact
2061.1exact
4093.2exact
60134.5exact
80186.8exact
100251.6exact
120331.3exact
140428.7exact

Data source & notes

PT asset ID
r428a
Original name
R-428A
CAS
Units
psig / F (atm: 14.6959 psi)
Default curve
dew
PT index version
v1(from /assets/pt/v1/index.json)
Safety note: PT lookups are a foundational building block for charging and diagnostics, but they do not replace OEM procedures or full system context.