REFRIGERANT • PT DATA v1

R-432A

PT data, curve stats, and quick routes into the field calculators. Data shown here is derived from the versioned PT asset set under /assets/pt/v1.

At a glance

SAFETY •
CURVE • dew
POINTS • 437
GWP
ODP
Curves available
Dew + Bubble
Pressure range (psig)
-14.69 to 625.95
Temperature range (°F)
-247 to 200
Note: PT points are stored in psig and °F. For blends, bubble and dew represent different saturation states. Always follow OEM charging procedures.

Quick actions

These routes are designed to be technician-friendly: minimal taps, prefilled context, and predictable URLs for bookmarks and sharing.

Open PT Chart
Fast lookup (pressure ↔ temp)
Open →
Browse Equipment
See equipment using this refrigerant
Open →
Superheat/Subcool
Preselect this refrigerant
Open →
Charge Calculator
Line set adjustments
Open →
Curve toggle
Tip: For blends, evaporator saturation is typically based on dew, and condenser saturation is typically based on bubble.

Pressure → Saturation temperature (quick)

Linear interpolation between nearest points. Out-of-range values show “—”.

Pressure (psig)Sat Temp (°F)Source
0-44.4linear
25-0.8linear
5024.8linear
7543.8linear
10059.2linear
15083.8linear
200103.5linear
250120linear
300134.3linear
350147.1linear
400158.6linear
450169.1linear

Temperature → Saturation pressure (quick)

Useful for “I have a target saturation temp—what pressure should I see?” checks.

Temp (°F)Sat Pressure (psig)Source
-401.7exact
-2011.7exact
025.6exact
2044.6exact
4069.5exact
60101.3exact
80141.3exact
100190.5exact
120250.1exact
140321.6exact

Data source & notes

PT asset ID
r432a
Original name
R-432A
CAS
Units
psig / F (atm: 14.6959 psi)
Default curve
dew
PT index version
v1(from /assets/pt/v1/index.json)
Safety note: PT lookups are a foundational building block for charging and diagnostics, but they do not replace OEM procedures or full system context.