REFRIGERANT • PT DATA v1

R-433A

PT data, curve stats, and quick routes into the field calculators. Data shown here is derived from the versioned PT asset set under /assets/pt/v1.

At a glance

SAFETY •
CURVE • bubble
POINTS • 511
GWP
ODP
Curves available
Dew + Bubble
Pressure range (psig)
-14.7 to 603.6
Temperature range (°F)
-310 to 200
Note: PT points are stored in psig and °F. For blends, bubble and dew represent different saturation states. Always follow OEM charging procedures.

Quick actions

These routes are designed to be technician-friendly: minimal taps, prefilled context, and predictable URLs for bookmarks and sharing.

Open PT Chart
Fast lookup (pressure ↔ temp)
Open →
Browse Equipment
See equipment using this refrigerant
Open →
Superheat/Subcool
Preselect this refrigerant
Open →
Charge Calculator
Line set adjustments
Open →
Curve toggle
Tip: For blends, evaporator saturation is typically based on dew, and condenser saturation is typically based on bubble.

Pressure → Saturation temperature (quick)

Linear interpolation between nearest points. Out-of-range values show “—”.

Pressure (psig)Sat Temp (°F)Source
0-48linear
25-2.9linear
5023.5linear
7543linear
10058.9linear
15084.2linear
200104.4linear
250121.4linear
300136.1linear
350149.2linear
400161.1linear
450171.9linear

Temperature → Saturation pressure (quick)

Useful for “I have a target saturation temp—what pressure should I see?” checks.

Temp (°F)Sat Pressure (psig)Source
-403.1exact
-2013.3exact
027.3exact
2046.2exact
4070.7exact
60101.9exact
80140.7exact
100188.3exact
120245.7exact
140314.2exact

Data source & notes

PT asset ID
r433a
Original name
R-433A
CAS
Units
psig / F (atm: 14.6959 psi)
Default curve
dew
PT index version
v1(from /assets/pt/v1/index.json)
Safety note: PT lookups are a foundational building block for charging and diagnostics, but they do not replace OEM procedures or full system context.