REFRIGERANT • PT DATA v1
R-436B
PT data, curve stats, and quick routes into the field calculators. Data shown here is derived from the versioned PT asset set under /assets/pt/v1.
At a glance
SAFETY • A3
CURVE • bubble
POINTS • 481
GWP
3.16
ODP
Curves available
Dew + Bubble
Pressure range (psig)
-14.69 to 588.6
Temperature range (°F)
-252 to 240
Note: PT points are stored in psig and °F. For blends, bubble and dew represent different saturation states. Always follow OEM charging procedures.
Quick actions
These routes are designed to be technician-friendly: minimal taps, prefilled context, and predictable URLs for bookmarks and sharing.
Pressure → Saturation temperature (quick)
Linear interpolation between nearest points. Out-of-range values show “—”.
| Pressure (psig) | Sat Temp (°F) | Source |
|---|---|---|
| 0 | -27.9 | linear |
| 25 | 20.5 | linear |
| 50 | 48.9 | linear |
| 75 | 70.1 | linear |
| 100 | 87.2 | linear |
| 150 | 114.6 | linear |
| 200 | 136.6 | linear |
| 250 | 155.1 | linear |
| 300 | 171.2 | linear |
| 350 | 185.6 | linear |
| 400 | 198.7 | linear |
| 450 | 210.6 | linear |
Temperature → Saturation pressure (quick)
Useful for “I have a target saturation temp—what pressure should I see?” checks.
| Temp (°F) | Sat Pressure (psig) | Source |
|---|---|---|
| -40 | -3.7 | exact |
| -20 | 2.9 | exact |
| 0 | 12.1 | exact |
| 20 | 24.7 | exact |
| 40 | 41.2 | exact |
| 60 | 62.4 | exact |
| 80 | 88.9 | exact |
| 100 | 121.7 | exact |
| 120 | 161.3 | exact |
| 140 | 208.7 | exact |
Data source & notes
PT asset ID
r436bOriginal name
R-436B
CAS
—
Units
psig / F (atm: 14.6959 psi)
Default curve
dew
PT index version
v1(from /assets/pt/v1/index.json)Safety note: PT lookups are a foundational building block for charging and diagnostics, but they do not replace OEM procedures or full system context.