REFRIGERANT • PT DATA v1
R-437A
PT data, curve stats, and quick routes into the field calculators. Data shown here is derived from the versioned PT asset set under /assets/pt/v1.
At a glance
SAFETY • A1
CURVE • bubble
POINTS • 357
GWP
ODP
Curves available
Dew + Bubble
Pressure range (psig)
-14.59 to 547.04
Temperature range (°F)
-156 to 200
Note: PT points are stored in psig and °F. For blends, bubble and dew represent different saturation states. Always follow OEM charging procedures.
Quick actions
These routes are designed to be technician-friendly: minimal taps, prefilled context, and predictable URLs for bookmarks and sharing.
Pressure → Saturation temperature (quick)
Linear interpolation between nearest points. Out-of-range values show “—”.
| Pressure (psig) | Sat Temp (°F) | Source |
|---|---|---|
| 0 | -26.2 | linear |
| 25 | 17.5 | linear |
| 50 | 42.9 | linear |
| 75 | 61.6 | linear |
| 100 | 76.7 | linear |
| 150 | 100.7 | linear |
| 200 | 119.7 | linear |
| 250 | 135.7 | linear |
| 300 | 149.5 | linear |
| 350 | 161.7 | linear |
| 400 | 172.7 | linear |
| 450 | 182.7 | linear |
Temperature → Saturation pressure (quick)
Useful for “I have a target saturation temp—what pressure should I see?” checks.
| Temp (°F) | Sat Pressure (psig) | Source |
|---|---|---|
| -40 | -4.5 | exact |
| -20 | 2.5 | exact |
| 0 | 12.6 | exact |
| 20 | 27 | exact |
| 40 | 46.6 | exact |
| 60 | 72.6 | exact |
| 80 | 106 | exact |
| 100 | 148.3 | exact |
| 120 | 200.8 | exact |
| 140 | 265 | exact |
Data source & notes
PT asset ID
r437aOriginal name
R-437A
CAS
—
Units
psig / F (atm: 14.6959 psi)
Default curve
dew
PT index version
v1(from /assets/pt/v1/index.json)Safety note: PT lookups are a foundational building block for charging and diagnostics, but they do not replace OEM procedures or full system context.