REFRIGERANT • PT DATA v1

R-501

PT data, curve stats, and quick routes into the field calculators. Data shown here is derived from the versioned PT asset set under /assets/pt/v1.

At a glance

SAFETY •
CURVE • dew
POINTS • 436
GWP
ODP
Curves available
Dew + Bubble
Pressure range (psig)
-14.69 to 642.5
Temperature range (°F)
-239 to 200
Note: PT points are stored in psig and °F. For blends, bubble and dew represent different saturation states. Always follow OEM charging procedures.

Quick actions

These routes are designed to be technician-friendly: minimal taps, prefilled context, and predictable URLs for bookmarks and sharing.

Open PT Chart
Fast lookup (pressure ↔ temp)
Open →
Browse Equipment
See equipment using this refrigerant
Open →
Superheat/Subcool
Preselect this refrigerant
Open →
Charge Calculator
Line set adjustments
Open →
Curve toggle
Tip: For blends, evaporator saturation is typically based on dew, and condenser saturation is typically based on bubble.

Pressure → Saturation temperature (quick)

Linear interpolation between nearest points. Out-of-range values show “—”.

Pressure (psig)Sat Temp (°F)Source
0-41linear
252.3linear
5027.5linear
7546.1linear
10061.2linear
15085.2linear
200104.2linear
250120.2linear
300134.1linear
350146.5linear
400157.6linear
450167.7linear

Temperature → Saturation pressure (quick)

Useful for “I have a target saturation temp—what pressure should I see?” checks.

Temp (°F)Sat Pressure (psig)Source
-400.4exact
-209.8exact
023.2exact
2041.6exact
4066.1exact
6097.9exact
80138.1exact
100188.1exact
120249.2exact
140323.1exact

Data source & notes

PT asset ID
r501
Original name
R-501
CAS
Units
psig / F (atm: 14.6959 psi)
Default curve
dew
PT index version
v1(from /assets/pt/v1/index.json)
Safety note: PT lookups are a foundational building block for charging and diagnostics, but they do not replace OEM procedures or full system context.